Purpose : To evaluate the accuracy of ocular sonography in measurement of size of intraocular foreign bodies (IOFB)

Methods : In a case series study, 58 consecutive patients with intraocular foreign body were included. Ocular sonography was performed to detect intraocular foreign body and the results were compared with the same intraoperative findings.

Results : Metallic material was found to be the most prevalent one (71%) followed by glasses (12%), stone (8%) and wood (6%). Ultrasound localized the foreign body lodged in the lens in 10.3%, in the angle in 3.4% and in the vitreous or vitreoretinal region in the rest of them (86.3%). The mean size measured by ocular sonography was 3.5×4.5 mm and that was reported by the surgeon was 2.9×4 mm. While the reports of sonography in detection and localization of IOFB was completely comparable with surgical findings, size measurements were considerably different from true measurements after intraocular surgery.

Conclusion : Ocular sonography showed mostly overestimation in measuring intraocular foreign bodies. Although ocular sonography was one of the best methods for assessment of IOFB, it doesn't have high accuracy in estimation of size of IOFB.

 

Iranian Journal of Ophthalmology 200820(4):20-23
Keywords: Sonography, Foreign Body, Intraocular
Full-Text [PDF 49 kb]   (2913 Downloads)    
Type of Study: Original | Subject: General
Send email to the article author

Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Farvardin M, Mehryar M, Karanjam M, Ashraf H, Mehdizadeh M, Rahimi M, et al . The Accuracy of Ocular Sonography in Detection and Measurement of Intraocular Foreign Bodies. Iranian Journal of Ophthalmology. 2008; 20 (4) :20-23
URL: http://irjo.org/article-1-187-en.html


Volume 20, Issue 4 (Iranian Journal of Ophthalmology 2008) Back to browse issues page
مجله چشم پزشکی ایران Iranian Journal of Ophthalmology
Persian site map - English site map - Created in 0.06 seconds with 31 queries by YEKTAWEB 4071