[Home ] [Archive]   [ فارسی ]  
:: Volume 25, Issue 2 (Iranian Journal of Ophthalmology 2013) ::
2013, 25(2): 133-138 Back to browse issues page
Efficacy of Intacs Intrastromal Corneal Ring Segments in Patients with Post-LASIK Corneal Ectasia
Amirhushang Beheshtnejad Dr., Alireza Yazdani-Abyaneh Dr., Hassan Hashemi Dr. * , Mahmoud Jabbarvand Dr., Alireza Fahim Dr., Masoud Aghsaei Fard Dr.
, hhashemi@noorvision.com
Abstract:   (7235 Views)

Purpose : To investigate the efficacy of Intacs implantation in post-LASIK corneal ectasia (PLE)

Methods : In this retrospective study, 17 eyes of 12 patients with PLE, that had been implanted Intacs, were evaluated. These parameters were assessed: uncorrected visual acuity (UCVA), best spectacle corrected visual acuity (BSCVA), manifest refractive spherical equivalent (MRSE), refractive cylinder (RC), mean Keratometry (Km), and topographic cylinder (TC). Also preoperatively, thinnest point thickness (TPT) was measured with rotating Scheimpflug camera. The results of single and double-segment Intacs implantation were also reported.

Results : Mean UCVA logMAR value improved from 0.93±0.41 to 0.57±0.34 (p=0.007), and BSCVA logMAR from 0.36±0.34 to 0.18±0.18 (p=0.007). MRSE reduced from 4.15±2.71 to 2.48±1.57 diopter (D) (p=0.003), and Km from 44.57±3.93 to 43.00±3.96 D (p=0.003). RC changed from 2.65±1.91 to 2.59±1.12 D (p=0.776), and TC from 2.81±1.71 to 2.44±1.41 D (p=0.365), neither change was statistically significant. BSCVA and UCVA improved in both single and double-segment groups.

Conclusion : Intacs implantation can improve UCVA and BSCVA in cases of PLE, except when TPT is less than 350 microns. Both MRSE and Km reduced after surgery but astigmatism did not change.

  

Iranian Journal of Ophthalmology 201325(2):133-138 © 2013 by the Iranian Society of Ophthalmology

Keywords: Ectasia, Intacs, LASIK, Corneal Ectasia, Astigmatism
Full-Text [PDF 314 kb]   (1476 Downloads)    
Type of Study: Original | Subject: Anterior segment
Send email to the article author

Add your comments about this article
Your username or Email:

Write the security code in the box >


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Beheshtnejad A, Yazdani-Abyaneh A, Hashemi H, Jabbarvand M, Fahim A, Aghsaei Fard M. Efficacy of Intacs Intrastromal Corneal Ring Segments in Patients with Post-LASIK Corneal Ectasia. Iranian Journal of Ophthalmology. 2013; 25 (2) :133-138
URL: http://irjo.org/article-1-814-en.html


Volume 25, Issue 2 (Iranian Journal of Ophthalmology 2013) Back to browse issues page
مجله چشم پزشکی ایران Iranian Journal of Ophthalmology
Persian site map - English site map - Created in 0.05 seconds with 30 queries by YEKTAWEB 3638